Microwave Data Systems MDS entraNET 2400 Instalační příručka Strana 10

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 15
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 9
System Part Number: 900-0782-81, -91
Document P/N: 551-0782-81, Rev C1
December 2014
Installation Guide
Peninsula Engineering Solutions may change specifications as necessary to meet industry requirements. © 2014 Peninsula Engineering Solutions, inc.
Hit <ESC> for the previous menu, then type ‘B’ for the Advanced Configuration. Select ‘B’ for
Direct Mode.
Direct Mode Menu as shown at the UHF Telemetry Transmitter end.
Selection Item Description – For UHF Telemetry Transmitter, RF Repeater end.
A DEFAULT Factory setting: Default direct state is direct mode
B MODE Factory setting: Enter direct mode
C TYPE Factory setting: Operate as the single root remote.
D NETADDR
All units on the same network must use the same address. Both ends of the
RMAS-120-81 UHF Telemetry Link must use the same address. Make same as entered
on the Basic screen.
E PWR +20 to +30 dBm in 1 dB steps. Setting carries over from basic menu.
F BAND 2400 MHz only, select A, B or C. Transmitter and Receiver must match.
Direct Mode Menu as shown at the
UHF Telemetry Receiver end.
Peninsula Engineering Solutions, inc. Telephone +1 925 837-2243
POB 1095 Facsimile +1 925 837-2298
Danville, California 94526, USA Internet www.peninsulaengineering.com
Zobrazit stránku 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15

Komentáře k této Příručce

Žádné komentáře